S1202S
S1202S / 0R2697 / 0R4267 / 10R1914 / 10R9816 / 3604658 / 3604658RX / 10455855 / 10457078 / 10461732 / 10465601 / 10478823 / 10478850 / 10478853 / 10478855 / 10478859 / 10478861 / 10479144 / 10479342 / 1990233 / 1990234 / 1990291 / 1993753 / 8200480 / 8200545 / 8200578 / STD9342CL / STD9342ES / M128R3821SE / 3902N / STR80170
Elecdura
Available for qualified orders
20 pcs
7 - 15 Days
Neutral packaging / private-label review
18 Months
S1202S / 0R2697 / 0R4267 / 10R1914 / 10R9816 / 3604658 / 3604658RX / 10455855 / 10457078 / 10461732 / 10465601 / 10478823 / 10478850 / 10478853 / 10478855 / 10478859 / 10478861 / 10479144 / 10479342 / 1990233 / 1990234 / 1990291 / 1993753 / 8200480 / 8200545 / 8200578 / STD9342CL / STD9342ES / M128R3821SE / 3902N / STR80170
Caterpillar 3512 engine applications using the supplier-defined 24V 9.0kW 11T CW starter with a module-4.233 drive
Confirm 24V, 9.0kW, 11T, CW, module 4.233, 3 × Ø16.5 mounting holes, Ø92 locating diameter, 47 mm drive-end distance, mounting orientation and terminal layout against the removed starter before volume supply.
| Availability: | |
|---|---|
| Quantity: | |
Caterpillar engine distributors, mining operators and high-output starter buyers can use S1202S as the commercial identity for the starter required in Caterpillar 3512 engine. The order should preserve the 11T pinion and the 24V 9.0kW 11T module-4.233 starter for Caterpillar 3512 engines, avoiding a broad substitution based only on engine family or overall housing appearance.
Send the full S1202S application and old-unit identification rather than only a truck or engine brand. With mounting and terminal photos, quantity, destination and arrival target, Elecdura can discuss the correct starter, MOQ, packing, warranty and shipping route without unnecessary follow-up.
| Primary OE reference | S1202S |
| Target application | Caterpillar 3512 engine applications |
| Voltage and output | 24V / 9.0kW |
| Pinion and rotation | 11T / module 4.233 / CW |
| Mounting-hole reference | 3 × Ø16.5 mounting holes |
| Drive-end reference | Ø92 locating diameter; 47 mm drive-end distance; Ø146 mounting-hole circle |
| OE and cross-reference group | S1202S / 0R2697 / 0R4267 / 10R1914 / 10R9816 / 3604658 / 3604658RX / 10455855 / 10457078 / 10461732 / 10465601 / 10478823 / 10478850 / 10478853 / 10478855 / 10478859 / 10478861 / 10479144 / 10479342 / 1990233 / 1990234 / 1990291 / 1993753 / 8200480 / 8200545 / 8200578 / STD9342CL / STD9342ES / M128R3821SE / 3902N / STR80170 |
| Wholesale terms | MOQ 20 pcs / normally 7–15 days after order confirmation |
| Warranty | 18 months under agreed sales terms |
For S1202S first-lot sampling, place the old and new starters in the same front-facing position. Check 3 × Ø16.5 mounting holes, Ø92 locating diameter, Ø146 mounting-hole circle and 47 mm drive-end distance. Keeping those values with arrival photographs gives purchasing a reusable physical record for later replenishment.
After the S1202S mounting check, verify 24V, 9.0kW, 11T and CW with module 4.233. The final visual review covers the terminal studs, control connector and pinion. This prevents a physically related starter from being approved only because its reference appears in the same family.
For a bulk order of S1202S, Elecdura confirms availability, packing, lead time and freight against the required quantity and destination. Standard terms begin at 20 pieces, normally require 7–15 days after confirmation and include an 18-month warranty under the final sales agreement.
For multi-branch supply, show which quantity is needed immediately and which can follow as planned replenishment. The accepted S1202S sample, dimensional record and terminal photographs can then support carton marking, receiving checks and repeat orders across the customer’s network.
B2B buyers can use the video to review Elecdura’s starter-motor assembly and test process. The approved S1202S configuration remains defined by 24V, 9.0kW, 11T, CW, mounting geometry and terminals, which should be retained in the purchase record.
Place the removed starter and S1202S on the same mounting-face orientation. Compare Ø92 locating diameter, Ø146 mounting-hole circle, the 3 × Ø16.5 mounting holes and the 47 mm drive-end distance. The drawing is a dimensional reference rather than a scale template, so use suitable measuring tools and verify the terminals separately.
Separate planned maintenance demand from breakdown coverage and new-account stock. Share the number of supported machines, recent S1202S usage, transfer time between branches and the desired reserve. The resulting order can combine immediate units and scheduled replenishment while keeping the application and physical specification clearly identified.
For S1202S, ask the workshop for the removed starter label and the exact equipment record. Match 24V, 9.0kW, 11T and CW, then compare the locating diameter, mounting holes and terminals. If one of those items changes, request another quotation instead of accepting the similar housing.
The references identify a related sourcing family, not automatic interchangeability. Use S1202S, 0R2697, 0R4267, 10R1914, 10R9816 to locate possible matches, then confirm 24V, 9.0kW, 11T, CW and the mounting face. Any difference in drive position, terminal layout or locating diameter requires a separate product decision.
Record battery voltage at rest and during the start attempt, then test both main cables under load. Check grounds, terminal tightness and the control feed to the solenoid. Supplying those readings with an enquiry for S1202S helps the workshop avoid replacing a sound starter when the actual fault is elsewhere.
Use a first-lot sample to confirm S1202S, 24V, 9.0kW, 11T and CW. Inspect the mounting face, terminals and protective packing, then retain the lot reference and images. This gives warehouse and sales teams a shared record before units are distributed to branches or workshops.
List S1202S together with the supported equipment record, 24V, 9.0kW, 11T and CW. Send old-unit photos, order volume, destination and requested timing, plus any private-label or staged-delivery requirement. This keeps the technical selection and the commercial offer aligned from the first response.
For S1202S, provide the delivery lot, installation date, operating hours and a clear fault description. Include photographs of the label, pinion, mounting face and terminals, together with battery and voltage-drop results under cranking load. These records help separate product condition from application, installation, electrical-system or transport-related causes.
Email info@elecdurauto.com with S1202S, the supported Caterpillar 3512 engine record, old-unit photographs, quantity, destination and required arrival date. Elecdura will use those details to confirm the 24V, 9.0kW, 11T CW starter and prepare wholesale pricing with MOQ, lead time, packing and freight.