The SA-4561-T Kubota Fuel Shutdown Solenoid is supplied for mixed Kubota engine programs, generator service, compact equipment repair, and CT equipment reference buyers. The part supports fuel cut-off and engine shutdown control, while buyers usually search by OE number, equipment reference, voltage, and physical structure before requesting price.
Buyers often search by SA number, 29-70167-00, 1503ES, V1505, and D1105, while voltage separation remains a key quotation requirement.
SA-4561-T may be requested as 12V or 24V. Wrong voltage can cause no actuation, overheating, or coil failure, so old label and voltage confirmation are mandatory.
Elecdurauto can check fuel shutdown solenoids together with other diesel engine electrical parts when a complete OE list, quantities, and old product photos are provided.
| Specification | Details |
| Product Name | Kubota Fuel Shutdown Solenoid |
| Main OE Number | SA-4561-T |
| Cross Reference | 29-70167-00, 1503ES-12A5UC9S, 1503ES-24A5UC9S |
| Product Category | Fuel Shutoff Solenoid / Stop Solenoid / Shutdown Solenoid |
| Voltage | 12V / 24V versions should be confirmed by OE number and old label |
| Application Brand | Kubota / CT equipment references |
| Application References | V1505, D1105, D905, D1005, V1205, V1305, CT 4.91, CT 3.69 |
| Main Function | Fuel cut-off and diesel engine stop control |
| Order Type | Bulk replacement supply for mixed Kubota engine programs, generator service, compact equipment repair, and CT equipment reference buyers |
SA-4561-T should be matched by exact OE number and physical confirmation. Related references such as 29-70167-00, 1503ES-12A5UC9S, 1503ES-24A5UC9S may appear in sourcing files, but connector, voltage, mounting, and plunger details still need checking.
| Reference Item | Details |
| Main OE Number | SA-4561-T |
| Related References | 29-70167-00, 1503ES-12A5UC9S, 1503ES-24A5UC9S |
| Common Search Name | SA-4561-T fuel shutdown solenoid |
| Also Known As | Fuel shutoff solenoid / stop solenoid / engine shutdown solenoid |
| Purchase Check | OE label, voltage, connector, mounting body, plunger end, and old product photo |
| Brand / Channel | Model or Reference | Notes |
| Kubota | V1505 | Confirm SA-4561-T and voltage version |
| Kubota | D1105, D905, D1005 | Check old solenoid label and product photo |
| Kubota | V1205, V1305 | Engine reference requires physical confirmation |
| CT equipment references | CT 4.91 / CT 3.69 catalog notes | Use OE number and old photos for final matching |
For B2B purchasing, the inquiry should be built around confirmed OE numbers and old-part comparison rather than product name alone.
| Information to Send | Details |
| OE number or part number | SA-4561-T, 29-70167-00, 1503ES-12A5UC9S, 1503ES-24A5UC9S |
| Voltage | 12V / 24V versions should be confirmed by OE number and old label |
| Equipment or engine reference | V1505, D1105, D905, D1005, V1205, V1305, CT 4.91, CT 3.69 |
| Old part photo | Full product photo, connector side, mounting side, plunger end, and label photo |
| Quantity | Required pieces for each reference number |
| Destination country | Needed for freight, carton, and packing discussion |
| Packing request | Neutral box, part-number label, customer label, or mixed-model carton marking |
SA-4561-T is suitable for distributors handling mixed engine stop-solenoid programs across compact machines, generator sets, and CT equipment references.
Buyers often search by SA number, 29-70167-00, 1503ES, V1505, and D1105, while voltage separation remains a key quotation requirement.
Clear OE-focused information helps buyers understand where the part belongs, which OE numbers should be checked, and what information is required before quotation. That reduces repeated messages and improves inquiry quality.
SA-4561-T may be requested as 12V or 24V. Wrong voltage can cause no actuation, overheating, or coil failure, so old label and voltage confirmation are mandatory.
When a buyer sends only a machine name, sample checking is recommended. A clean purchasing file should include OE number, voltage label, connector view, mounting side, rod end, quantity, and packing request.
Bulk shutdown solenoid shipments should be checked for electrical response, movement stability, connector condition, mounting layout, label accuracy, and packing separation.
| Check Item | What We Check |
| Voltage response | Check the order-required voltage version |
| Pull-in movement | Actuation response, travel condition, and release behavior |
| Connector | Plug shape, terminal layout, wire direction, and terminal condition |
| Mounting structure | Body orientation, bracket position, hole structure, and installation side |
| Plunger / rod | Length, end structure, movement, and return condition |
| Label | OE number, customer label, and carton identification |
| Packing | Individual packing, carton packing, and mixed-model separation |
SA-4561-T is suitable for distributors handling mixed engine stop-solenoid programs across compact machines, generator sets, and CT equipment references.
For mixed stock orders, accurate model labeling and OE-number separation are important because similar shutdown solenoids may look close but use different mounting, connector, voltage, or plunger details.
Yes. SA-4561-T should be used as the main quotation reference, together with related numbers such as 29-70167-00, 1503ES-12A5UC9S, 1503ES-24A5UC9S when they appear in the buyer list.
The catalog lists V1505, D1105, D905, D1005, V1205, V1305, CT 4.91, CT 3.69. Final fitment should be confirmed by OE number, old label, connector, mounting structure, and product photos.
Similar stop solenoids may use different voltage, terminals, mounting bodies, or rod ends. Photos reduce wrong-product risk before sample or bulk order approval.
Yes. The product can be supplied for mixed Kubota engine programs, generator service, compact equipment repair, and CT equipment reference buyers, with reference labels and carton separation when required.
The catalog lists SA-4561-T, 29-70167-00, 1503ES-12A5UC9S, and 1503ES-24A5UC9S. Confirm voltage before ordering.
Yes, but they must be listed and packed separately. Wrong voltage can cause no actuation, overheating, or coil failure.
Neutral packing, part-number labels, and customer labels can be discussed based on quantity and model availability. Clear labeling helps avoid mix-ups in mixed-model shipments.
Send OE numbers, equipment model, voltage, old product photos, quantity, destination country, and packing requirements.
Send your OE number list, old product photos, voltage requirements, equipment or engine references, order quantity, packing request, and destination country. Elecdurauto will check replacement options and prepare a bulk quotation for Kubota Fuel Shutdown Solenoid and related diesel engine electrical parts.