Elecdurauto Volvo HVAC blower power stage (blower motor resistor module) is designed to regulate blower speed smoothly and reliably under long HVAC duty cycles. This unit features a curved aluminum pin heat sink to dissipate heat efficiently and an OE-style connector interface for accurate matching—ideal for distributors and importers managing bulk inventory.
20443826
IATF 16949, ISO 9001, and other major OEM certification systems
OEM label and ODM customization accepted
100 pcs
7–15 Days
18 months
| Availability: | |
|---|---|
| Quantity: | |
Product Description
A blower power stage (also called a blower motor resistor module) regulates electrical power to the HVAC blower motor to achieve smooth fan speed control. Compared with open-coil resistor plates, a power stage typically provides more stable speed regulation and uses a heat sink to manage thermal load.
OE-level aftermarket replacement for Volvo 20443826 blower power stage
Aluminum pin heat sink improves thermal stability during continuous operation
OE-style connector layout supports faster fitment verification
Fitment verification support by OE + connector photo + mounting points
Bulk supply for importers/distributors (MOQ 100)

| Reference Type | Part Number | Notes |
|---|---|---|
| Primary OE (Volvo) | 20443826 | Main OE number for sourcing and verification |
| Trade / Reference | 351332-391 | Common trade number format used for cross-search |
| Additional cross refs | Available on request | Provide original part photos for confirmation |
Important notice : OE / interchange numbers are for reference only. Please confirm fitment by OE number + connector layout + mounting pattern before ordering.
| Brand | Fitment Scope | Notes |
|---|---|---|
| Volvo | Volvo HVAC blower systems | Volvo HVAC revisions vary; verify by OE + connector + mounting |
| Parameter | Specification |
|---|---|
| Product type | HVAC blower power stage / blower motor resistor module |
| OE reference | 20443826 |
| Trade reference | 351332-391 |
| System voltage | Typical 12V Volvo passenger HVAC |
| Heat dissipation | Curved aluminum pin heat sink |
| Connector | OE-style multi-pin plug (verify layout) |
| Function | Smooth HVAC blower motor speed regulation |
| Warranty | 18 months |
| MOQ | 100 pcs |
Stable resistance performance under continuous HVAC blower loads, supporting consistent fan speeds in truck HVAC systems.

Improves airflow around the resistor element to enhance heat dissipation and reduce overheating risk.

Designed for vibration resistance and stable installation on heavy-duty trucks and commercial vehicles.

Common symptoms of a faulty blower motor resistor include:
Only one fan speed works
Blower runs intermittently or stops
No airflow from vents
Burnt connector or overheating smell
Unstable cabin temperature control
Confirm terminal layout and mounting pattern before installation
Replace melted connector housing if overheating occurred
If repeat failures happen, inspect blower motor current draw and wiring resistance
Professional installation recommended for workshops and fleet environments
From a manufacturer's standpoint, the most common field issues come from overheating and poor terminal contact. Our batch-level controls focus on:
Resistance stability and electrical continuity checks
Terminal contact and alignment inspection
Assembly consistency for bracket positioning
Heat endurance verification for production batches

For distributors and importers, stable packaging and shipment execution matter as much as product quality. We prepare bulk orders with export-standard carton packing, palletizing, and container loading. Before shipment, we can share loading photos and packing details to help you manage receiving and warehouse operations.
Export-grade cartons with clear carton marks (OE No. / qty / batch)
Palletizing + stretch wrap to reduce damage during long-distance transport
Container loading with space optimization for bulk shipments
Mixed-SKU consolidation support (send your part list for packing plan)
Shipment photos available for your receiving & documentation process
MOQ note: MOQ is 100 pcs per item. For bulk orders, share your destination port and order mix—we'll propose an efficient packing and loading plan.




For distributors and importers, the key to a smooth first order is fast and accurate fitment confirmation. Our dedicated sample room keeps resistor blocks and related HVAC electrical parts organized by OE reference and application. This enables quick cross-checking of connector layout, mounting pattern, and structure, so you can reduce wrong-fit risk and shorten purchasing cycles.
Faster OE and application verification before bulk production
Quick photo support (connector & bracket details) for your internal approval
Sample availability for evaluation and comparison
Better accuracy for distributor listings and warehouse SKU management
Reduced returns caused by mismatched connectors or mounting holes
Send your OE number / reference number, photos of the original part (if available), and target quantity. We'll confirm match and advise the most suitable option for your market.
MOQ: 100 pcs for bulk orders. We support B2B export packaging suitable for importer/distributor warehousing.
To quote efficiently, please send:
OE number: 20443826
Quantity (MOQ 100 pcs)
Destination / port
Connector & bracket photos (recommended for fast confirmation)
Match OE 20443826 plus connector layout and arc-shaped mounting points. The curved housing profile is a key identifier for this module type.
A power stage is an electronic blower speed controller module (often with heat sink cooling) that provides smoother regulation. A resistor plate uses stepped resistance stages and relies more on airflow cooling.
Pin-fin heat sinks increase surface area, helping dissipate heat generated during speed control. This improves stability during long HVAC operation, especially in warm environments and continuous use.
Common symptoms include no blower, intermittent airflow, speed not responding, or blower stuck at one speed—often linked to thermal stress or connector contact issues.
Wrong orders usually come from different mounting hole positions or connector keying differences between revisions. Photo verification is recommended for bulk orders.
Check blower motor current draw, cabin filter blockage, and connector heat damage. High motor load or poor contact can overheat a new module.
Yes. If the vehicle-side plug shows melting/discoloration, replacing the connector housing is recommended to restore proper contact and prevent repeat overheating.
Recommended QC includes connector pin alignment, mounting point consistency, heat sink integrity, and label verification for 20443826 / 351332-391.
Provide OE 20443826, quantity (MOQ 100), destination/port, and photos of connector + mounting points to avoid wrong-fit bulk orders.
Yes. For bulk orders we support neutral/branded packaging, barcode labeling, and listing-ready photos/content to help distributors launch faster.