Your Whole New Supply Chain For Heavy-Duty Parts
 E-mail :
 Whatsapp:
  +86 18915027366
 Phone:
  +86 18915027366
You are here: Home » Products » Fuel System & Turbo » Solenoid Valves » Diesel Fuel Shutoff Solenoids » Cummins Fuel Shutoff Solenoids » Fuel Shutdown Solenoid 3934174 3934177 for Cummins 5.9L
This product is no longer available

loading

Fuel Shutdown Solenoid 3934174 3934177 for Cummins 5.9L

3934174 12V and 3934177 24V SA-4697 shutdown solenoids for Cummins 5.9L engines. Confirm voltage, RE53559 cross-reference and mounting geometry.
  • 12V: 3934174 / SA-4697-12 / RE53559; 24V: 3934177 / SA-4697-24

  • OE-Equivalent Replacement Quality

  • IATF 16949 / ISO 9001 / CE / RoHS

  • 50 pcs

  • 7 - 15 Days

  • 12 Months

Availability:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

3934174 and 3934177 SA-4697 Cummins 5.9L Shutdown Solenoids

The SA-4697 family pairs 3934174 with 12V and 3934177 with 24V. RE53559 appears with the 12V configuration in shutdown-solenoid catalogs, yet cross-brand fitment still depends on the same rod, bracket and connector geometry.


3934174-3934177 Product Information

Item

Confirmed Information

Product Type

Fuel shutdown solenoid

OE / Reference Numbers

12V: 3934174 / SA-4697-12 / RE53559; 24V: 3934177 / SA-4697-24

Electrical Version

12V or 24V, selected by the SA-4697 group

Application Scope

Cummins 5.9L and related industrial shutdown applications with confirmed SA-4697 configuration

MOQ

50 pcs

Delivery Time

7 - 15 Days

Warranty

12 Months


Using RE53559 Carefully within the SA-4697 12V Group

Keep RE53559 beside 3934174 and SA-4697-12 only when the removed 12V solenoid shares the complete physical configuration. For 24V demand, use 3934177 or SA-4697-24 and exclude the 12V cross-reference.

Matching Point

Buyer Action

12V group

3934174 / SA-4697-12; verify RE53559 physically.

24V group

3934177 / SA-4697-24.

Bracket

Compare plate outline, hole centers and engine-side orientation.

Rod

Check resting length, joint, travel and direction.

Connector

Match terminal form and control-circuit function.


When a Cross-Reference Matches Electrically but Not Mechanically

Cross-brand numbers can lead to a correct voltage and coil concept while leaving the bracket or rod unusable. A candidate should be rejected if hole centers, output direction or installed clearance differs, even when the SA number appears in a catalog group.

Service or Order Situation

Recommended Review

Bracket holes miss

Do not modify the engine bracket; identify the correct configuration.

Rod points the wrong way

Treat the candidate as another SA variant.

Correct fit, weak action

Measure voltage under load and inspect linkage resistance.

Engine will not stop

Confirm full pump-lever movement and rod adjustment.


Information Needed for a Precise 3934174-3934177 Quote

State the SA-4697 voltage group, RE53559 only if present, Cummins application, bracket, rod, connector and quantity.

RFQ Item

What to Provide

OE / reference

12V: 3934174 / SA-4697-12 / RE53559; 24V: 3934177 / SA-4697-24

Voltage

12V or 24V, selected by the SA-4697 group

Application

Cummins 5.9L and related industrial shutdown applications with confirmed SA-4697 configuration

Photos

Old label, connector face, mounting bracket, rod or cable end and one complete removed-part view

Commercial request

Quantity, destination market and packing requirement


3934174-3934177 Fuel Shutoff Solenoid FAQ

Is 3934174 the 12V SA-4697 solenoid?

Yes. 3934174 and SA-4697-12 form the verified 12V group used in Cummins 5.9L and related industrial demand. The old voltage and mechanical configuration should agree before the order is approved.


What is the 24V number for the SA-4697 family?

3934177 and SA-4697-24 identify the confirmed 24V group. Keep them on a separate order line from 3934174 so picking and packing controls preserve the electrical version.


How should RE53559 be used during sourcing?

RE53559 appears as a 12V supporting cross-reference in solenoid catalogs. It can narrow the search, but the bracket, rod end, connector and installed clearance must match before a Cummins or John Deere application is released.


Can a bracket be redrilled to fit a similar solenoid?

Modification can change alignment, rod travel and structural support, so it should not be used to turn an unmatched part into an approved replacement. Identify the correct SA configuration and mounting geometry instead.


Why can the rod move but the engine remain running?

The output may not carry the pump lever through its complete stop travel. Check joint play, rod adjustment, lever binding and bracket deflection while the solenoid is commanded to shut down.


What should accompany a 3934174/3934177 RFQ?

Send the full OE, voltage, Cummins engine and serial, any RE53559 marking, connector face, bracket-hole centers, rod dimensions, installed photo and quantity. State whether the failure is electrical, mechanical or intermittent.


Request a Quote for 3934174-3934177

Send the voltage-specific SA-4697 group, application details, cross-reference evidence and mounting measurements for quotation.

Previous: 
Next: 

Product Category

Related Products

content is empty!

Tell Us About Your Sourcing Needs

Share your product requirements, target market, and estimated order plan. Our team will help match suitable products and provide a fast quotation for your wholesale program.
Contact us
Heavy-Duty Parts. 
On Time. On Demand.
One-Stop Supplier in China
System
About
Contact Info
+86-189-1502-7366
A2 Block, Shimao Plaza, Changzhou, China
COPYRIGHT © 2025 ELECDURAUTO ALL RIGHTS RESERVED.