701959263
701959263
Elecdura
IATF 16949, ISO 9001, and other major OEM certification systems
OEM label and ODM customization accepted
100 pcs
7–15 Days
Neutral packaging / private-label review
18 months
701959263
VW Caddy MK2 1996–2003; Golf MK3 1992–2002; Passat 1994–1997; Polo 1995–2000; Transporter T4 1991–2004; Vento 1992–1998
For VW T4 orders, verify a non-A/C HVAC system and OE 701959263. Do not substitute 701959263A without confirming the original suffix and HVAC configuration.
| Availability: | |
|---|---|
| Quantity: | |
OE 701959263 identifies a series resistor for the fresh-air and heater blower circuit on selected Volkswagen applications. For Transporter T4 sourcing, the verified configuration boundary is a non-A/C HVAC system. Importers and distributors should keep the complete OE suffix, vehicle application and HVAC configuration together before combining demand or requesting a quotation.
The primary purchasing risk is not whether a similar resistor housing can be installed. It is whether the supplied unit matches the complete OE, connector interface, mounting geometry and intended HVAC configuration. Elecdura uses these identifiers to separate OE 701959263 from adjacent suffix versions before confirming a reference sample or bulk order.
Procurement Field | Controlled Information |
|---|---|
Primary OE | 701959263 |
Product Type | Blower motor resistor / fresh-air and heater blower series resistor |
T4 HVAC Boundary | Non-A/C configuration |
Adjacent Version | 701959263A is maintained as a separate product identity |
Technical Values Not Declared | Resistance, rated power, voltage, thermal-fuse temperature, material and pin count are not published without product-level evidence |
OE 701959263 covers the Volkswagen model and year ranges below. These applications support distributor cataloging and quotation screening, but they do not replace the complete OE and HVAC configuration check. When the removed part, vehicle record and requested suffix disagree, keep the inquiry separate until the physical interface and system configuration are confirmed.
Volkswagen Application | Controlled Year Range |
|---|---|
Caddy MK2 | 1996–2003 |
Golf MK3 | 1992–2002 |
Passat A2 / A5 | 1994–1997 |
Polo 6N1 / 6N2 / 6KV2 / 6KV5 | 1995–2000 |
Transporter MK4 / T4 | 1991–2004 |
Vento | 1992–1998 |
For T4 inquiries, include whether the vehicle has air conditioning. For the other listed applications, provide the complete OE from the removed component and clear connector and mounting views. This gives the quotation team enough information to identify a mismatch before it reaches reference-sample or bulk-order handling.
OE 701959263 and 701959263A must remain separate purchasing identities. A similar housing or a shared vehicle family does not establish interchangeability. The base OE has repeated support for non-A/C Transporter T4 applications, while the A-suffix is recorded separately and must not be merged into the same inventory line without exact product evidence.
Read the complete OE, including the final suffix, from the removed component or reliable vehicle record.
Confirm the vehicle model, year and HVAC configuration, with special attention to A/C versus non-A/C T4 systems.
Compare connector form, mounting geometry and housing details against the source part; do not approve a substitute from appearance alone.
Keep different suffixes separated in RFQs, sample labels, receiving records and distributor data until interchangeability is proven for the exact application.
This suffix discipline helps importers avoid mixed stock, incorrect application data and repeated clarification after goods arrive. It also gives private-label and catalog teams a stable OE identity for packaging, product data and repeat orders.
A blower that operates only at certain speeds can point technicians toward the resistor circuit, but the symptom does not identify the correct OE. Product identification and vehicle diagnosis remain separate decisions. Confirm OE 701959263 and the HVAC configuration first, then assess the condition of the surrounding blower circuit before treating a repeat failure as a replacement-part defect.
Blower motor current: excessive current draw can overheat the resistor and shorten replacement life.
Connector condition: heat-darkened terminals, loose contact or damaged wiring can create resistance and localized heating.
Airflow path: restricted airflow around the resistor can reduce heat dissipation and contribute to repeated thermal stress.
Reference-unit comparison: check the full OE, connector, mounting points and housing before accepting the unit as the purchasing reference.
For incoming inspection, compare the shipment with the confirmed reference unit and agreed label data. Resistance or power values should only become contractual inspection points when both parties have verified the measurement method and target value for OE 701959263; unsupported family-level figures should not be copied into a purchase specification.
No automatic interchange should be assumed. OE 701959263 and 701959263A identify separate resistor variants, so the final suffix remains part of the product identity. Compare the complete OE, HVAC configuration, connector form, mounting geometry and source-part photographs before combining the two numbers in an RFQ, distributor catalog or warehouse location.
Verified product references consistently associate OE 701959263 with Transporter T4 fresh-air and heater blower systems without air conditioning. A T4 model designation alone is not a sufficient order key because HVAC configuration and adjacent suffix versions can change the required resistor. Include the vehicle year, non-A/C confirmation and complete source OE with the inquiry.
Model and year narrow the application, but they do not uniquely identify the resistor. T4 production spans multiple years and HVAC arrangements, and the product family includes separate suffix variants. Use the complete OE, A/C or non-A/C configuration, connector view and mounting view together. This reduces the risk of quoting a visually similar resistor for the wrong blower system.
No. Missing or irregular blower speeds can justify testing the resistor circuit, but a symptom cannot prove which OE fits the vehicle. Diagnose the blower motor, resistor circuit, connector and wiring, then identify the replacement from the complete OE and HVAC configuration. Separating diagnosis from product identification prevents a correct diagnosis from leading to an incorrect part order.
Application coverage includes Caddy MK2 1996–2003, Golf MK3 1992–2002, Passat A2/A5 1994–1997, Polo 6N1/6N2/6KV2/6KV5 1995–2000, Transporter MK4 1991–2004 and Vento 1992–1998. Use these ranges for initial catalog screening, then confirm the complete OE and physical interface before treating an application as order-ready. For T4 demand, also retain the non-A/C configuration check.
Resistance and power values have not been established for this exact product identity. Elecdura therefore does not copy figures from a similar resistor family. If a buyer needs an electrical value as an inspection term, agree on a confirmed reference unit, test conditions and measurement method before quotation.
Compare the complete OE suffix, housing profile, connector interface, mounting geometry and intended vehicle/HVAC configuration. The reference should come from the identified application rather than a visually similar product. Record the confirmed observations in purchasing and quality documents so later shipments can be checked against the same identity without converting unverified resistance, power or pin data into contractual specifications.
Inspect the surrounding system before assuming the replacement resistor is the only cause. Check blower motor current draw, connector terminals for looseness or heat damage, wiring condition and the airflow path around the resistor. These checks help workshops and distributors distinguish a product issue from excessive electrical or thermal load that could damage another correctly identified 701959263 unit.
Send the complete OE, Volkswagen model and year, HVAC configuration, clear source-part photographs, required quantity, delivery destination and packaging or private-label requirements. For T4 demand, state non-A/C status explicitly. Elecdura can then return a quotation tied to the identified product, available supply terms and any reference-unit checks needed before a bulk order proceeds.
For an executable quotation, provide OE 701959263, the vehicle and year, A/C or non-A/C configuration, connector and mounting photographs, order quantity, destination and packaging requirements. If the inquiry includes 701959263A or another suffix, list it as a separate line until the configuration and physical interface have been confirmed.
Elecdura will review the supplied identity and application information, identify any missing product checks and return the commercial details available for the confirmed requirement. This approach supports distributor catalog accuracy, private-label preparation and repeat wholesale orders without merging adjacent resistor variants prematurely.