S0269
S0269 / 0001368078 / B001816426 / 369847 / STB4745MN / STR22090
Elecdura
Available for qualified orders
20 pcs
7 - 15 Days
Neutral packaging / private-label review
18 Months
S0269 / 0001368078 / B001816426 / 369847 / STB4745MN / STR22090
DAF 65 CF240 applications using the supplier-defined 24V 4.0kW 10T CW starter with a module-3.175 drive
Confirm 24V, 4.0kW, 10T, CW, module 3.175, 3 mounting holes shown as 11, 11, 11 mm, Ø89 mm locating diameter, 47 mm drive-end distance, mounting orientation and terminal layout against the removed starter before volume supply.
| Availability: | |
|---|---|
| Quantity: | |
S0269 defines stock for DAF 65 CF240 as 24V, 4.0kW, 10T and CW. Confirm 24V 4.0kW 10T module-3.175 catalog configuration before releasing a first order or replacing an approved sample.
Before comparing S0269 prices, state whether the request covers an initial sample, urgent breakdown demand or routine distributor replenishment. Include the full OE reference, application, photographs, quantity and destination so the offer remains connected to the physical unit the customer expects to receive.
| Primary OE reference | S0269 |
| Target application | DAF 65 CF240 applications |
| Voltage and output | 24V / 4.0kW |
| Pinion and rotation | 10T / module 3.175 / CW |
| Mounting-hole reference | 3 mounting holes shown as 11, 11, 11 mm |
| Drive-end reference | Ø89 mm locating diameter; 47 mm drive-end distance; Ø127 mm mounting-hole circle |
| OE and cross-reference group | S0269 / 0001368078 / B001816426 / 369847 / STB4745MN / STR22090 |
| Wholesale terms | MOQ 20 pcs / normally 7–15 days after order confirmation |
| Warranty | 18 months under agreed sales terms |
Compare S0269 at the 3 mounting holes shown as 11, 11, 11 mm, Ø127 mm mounting-hole circle and Ø89 mm locating diameter. The 47 mm drive-end distance helps verify where the pinion sits relative to the flange, while a straight terminal-side photograph confirms whether the main and control connections remain accessible after installation.
For S0269, record 10T, CW, 24V and 4.0kW, including module 3.175. Inspect the pinion, solenoid orientation and terminal access from the same side as the removed unit. A first sample should pass both the label check and this physical comparison.
For a bulk order of S0269, Elecdura confirms availability, packing, lead time and freight against the required quantity and destination. Standard terms begin at 20 pieces, normally require 7–15 days after confirmation and include an 18-month warranty under the final sales agreement.
Retain the accepted product view for planned commercial-fleet replenishment. Buyers should also state whether the order supports a single workshop, several branches or a fleet contract, allowing samples, safety stock, carton labels and staged dispatch to be planned around the actual service requirement.
B2B buyers can use the video to review Elecdura’s starter-motor assembly and test process. The approved S0269 configuration remains defined by 24V, 4.0kW, 10T, CW, mounting geometry and terminals, which should be retained in the purchase record.
Use the full old-unit number and DAF 65 CF240 record. Compare the 10T pinion, 3 mounting holes shown as 11, 11, 11 mm, Ø89 mm locating diameter and terminal side. Reject a candidate when its drive position, mounting face or cable connection differs.
Align the removed starter and S0269 at the mounting face. Compare Ø89 mm locating diameter, Ø127 mm mounting-hole circle, 3 mounting holes shown as 11, 11, 11 mm and 47 mm drive-end distance. Use the drawing for dimensions, measure with suitable tools and check terminals separately.
Use the complete alternate number, not a shortened series, and attach photographs of the removed unit. The S0269 group is acceptable only when 24V, 4.0kW, 10T, CW and the physical interface agree. A reference conflict should be clarified before samples or bulk quantities are released.
Measure cranking voltage and voltage loss across the positive and negative paths, not only open-circuit battery voltage. Review the solenoid command, cable terminals, engine ground and ring gear. The results provide a useful baseline for S0269 installation and for any later service discussion with the supplier.
Retain the accepted product view for planned commercial-fleet replenishment. Add recent usage, equipment population, transfer time and service level. Elecdura can then separate sample, emergency and replenishment quantities and plan packing or staged delivery around the buyer’s schedule.
Receiving should verify the S0269 label, quantity and packaging before opening sampled cartons. Compare the 10T drive, Ø89 mm locating diameter, mounting holes and terminal side with the approved record. Any damage, missing protection or physical mismatch should be quarantined with photographs and lot details for prompt review.
Provide the full reference and application, not only a broad brand name. Attach front, side and terminal views of the removed starter and state quantity, destination, required date and packaging needs. For S0269, Elecdura will respond with the matching specification, MOQ, availability, commercial terms and freight choices.
Submit the purchase reference, lot number, installation date and hours in service, then describe the symptom and operating conditions. Photographs and cranking-circuit measurements should accompany the report. This structured record gives Elecdura enough context to evaluate S0269 without assuming that every no-crank complaint originates inside the starter.
To discuss S0269 supply, send the complete application and old-unit identification, mounting-face and terminal photos, requested quantity, destination and timing to info@elecdurauto.com. The reply will address the specified starter, sample or bulk availability, export packing, commercial terms and delivery route.