Your Whole New Supply Chain For Heavy-Duty Parts
 E-mail :
 Whatsapp:
  +86 18915027366
 Phone:
  +86 18915027366
You are here: Home » Products » Rotating Electrical » Heavy Duty Starter Motors » CASE Starter Motor » S1024 CASE 880 Starter Motor Wholesale Supply

S1024 CASE 880 Starter Motor Wholesale Supply

Elecdura offers S1024 starter motor supply for CASE 880 excavator applications at 24V, 6.0kW, 10T and CW. Send the complete application and old-unit identification, front and terminal-side photographs, requested quantity and destination so samples, packing and delivery can be quoted accurately.
  • S1024

  • S1024 / 112169 / 112187 / A169694 / 3908594 / 10479108 / 1993903 / 1993914 / 1993954 / M105R3510SE / STR20016 / 6269R / 6269N

  • Elecdura

  • Available for qualified orders

  • 20 pcs

  • 7 - 15 Days

  • Neutral packaging / private-label review

  • 18 Months

  • S1024 / 112169 / 112187 / A169694 / 3908594 / 10479108 / 1993903 / 1993914 / 1993954 / M105R3510SE / STR20016 / 6269R / 6269N

  • CASE 880 excavator applications using the supplier-defined 24V 6.0kW 10T CW starter with a module-3.175 drive

  • Confirm 24V, 6.0kW, 10T, CW, module 3.175, 3 × Ø10 mounting holes, Ø89 locating diameter, 47 mm drive-end distance, mounting orientation and terminal layout against the removed starter before volume supply.

Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

S1024 Starter Motor Wholesale Application Support for CASE 880 excavator

For CASE 880 excavator, S1024 gives distributors a focused starting point for quotation and branch inventory. Confirm 24V, 6.0kW, 10T and CW, with particular attention to 24V 6.0kW 10T module-3.175 unit with the catalog-drawn Ø89 mounting face, before combining demand from different fleets or workshops.

Separate different old-unit numbers from the S1024 enquiry and attach images for each configuration. State which line is a sample and which is a replenishment quantity, together with destination and timing. This gives the quotation a practical fitment boundary and a realistic packing and delivery plan.


S1024 Starter Motor Mounting Reference for Commercial Buyers

Primary OE reference S1024
Target application CASE 880 excavator applications
Voltage and output 24V / 6.0kW
Pinion and rotation 10T / module 3.175 / CW
Mounting-hole reference 3 × Ø10 mounting holes
Drive-end reference Ø89 locating diameter; 47 mm drive-end distance; Ø127 mounting-hole circle
OE and cross-reference group S1024 / 112169 / 112187 / A169694 / 3908594 / 10479108 / 1993903 / 1993914 / 1993954 / M105R3510SE / STR20016 / 6269R / 6269N
Wholesale terms MOQ 20 pcs / normally 7–15 days after order confirmation
Warranty 18 months under agreed sales terms
S1024 CASE 880 excavator 24V 6.0kW 10T starter mounting dimensions
S1024 CASE 880 excavator 24V 6.0kW 10T starter mounting dimensions.

Check the S1024 drawing against the removed starter at the mounting face and drive end. The critical references are 3 × Ø10 mounting holes, Ø89 locating diameter, Ø127 mounting-hole circle and 47 mm drive-end distance. A physical mismatch should stop the unit from entering ordinary stock until the application is clarified.

The S1024 drive-end decision is completed by 10T, module 3.175 and CW, together with 24V and 6.0kW. Confirm main-terminal and control-terminal positions under the actual cable routing. Similar dimensions do not compensate for the wrong rotation, pinion or electrical rating.


S1024 Starter Motor Cross-Reference Boundary for Importers

The S1024 cross-reference group includes S1024, 112169, 112187, A169694, 3908594, 10479108, 1993903. These numbers improve search coverage across fleets and supplier systems, but they do not replace a check of 24V, 6.0kW, 10T, CW, mounting geometry and terminals.

If a mixed S1024 enquiry contains different pinions, drive positions or connector layouts, list each complete reference and photograph separately. Elecdura can then return distinct offers instead of placing unlike starters under one broad reference family.


S1024 Starter Motor Wholesale Ordering and Export Support

Elecdura can prepare S1024 orders for regional inventory, fleet workshops or industrial service demand. The standard starting point is 20 pieces, normally 7–15 days after order confirmation, with an 18-month warranty under agreed terms and packing selected for the destination and shipment method.

Buyers can state service urgency, supported equipment count and expected monthly use in the same RFQ. Elecdura can then discuss stock, production, packaging and staged delivery while maintaining the specified S1024 drive end and electrical rating throughout the order.

For supplier evaluation, the video presents Elecdura starter-motor assembly and testing. A S1024 order should still be released against the complete OE number, CASE 880 excavator details, electrical specification and physical comparison, giving purchasing both capability information and a clear product boundary.


S1024 Starter Motor Questions from Commercial Buyers

Why is a straight mounting-face photo useful for confirming S1024 during a CASE 880 service-network inspection?

Place the removed starter and S1024 on the same mounting-face orientation. Compare Ø89 locating diameter, Ø127 mounting-hole circle, the 3 × Ø10 mounting holes and the 47 mm drive-end distance. The drawing is a dimensional reference rather than a scale template, so use suitable measuring tools and verify the terminals separately.


When does a cross-reference related to S1024 need a separate quotation in a CASE 880 service-network sourcing program?

Use the complete alternate number, not a shortened series, and attach photographs of the removed unit. The S1024 group is acceptable only when 24V, 6.0kW, 10T, CW and the physical interface agree. A reference conflict should be clarified before samples or bulk quantities are released.


Why does S1024 require a physical comparison for CASE applications during service-network sourcing?

For S1024, ask the workshop for the removed starter label and the exact equipment record. Match 24V, 6.0kW, 10T and CW, then compare the locating diameter, mounting holes and terminals. If one of those items changes, request another quotation instead of accepting the similar housing.


Which cranking-circuit tests should precede replacement of S1024 in a CASE 880 service-network workshop?

Load-test the battery set and measure voltage drop on the positive and ground circuits while cranking. Inspect cable lugs, chassis grounds, the start-control signal and ring-gear condition before replacing S1024. These checks distinguish a starter fault from low battery capacity, resistance or a control-circuit problem.


Which operating factors should guide a fleet's S1024 reserve quantity in a CASE 880 service-network program?

Review workshop consumption by the stated CASE 880 excavator population instead of pooling every visually similar starter. Record monthly issues, lead-time exposure and the reserve required at each branch. That information supports a practical S1024 reorder point and avoids holding the wrong drive-end version as emergency stock.


What carton-to-product checks are appropriate for S1024 during a CASE 880 service-network receiving check?

Use a first-lot sample to confirm S1024, 24V, 6.0kW, 10T and CW. Inspect the mounting face, terminals and protective packing, then retain the lot reference and images. This gives warehouse and sales teams a shared record before units are distributed to branches or workshops.


Which details allow Elecdura to quote S1024 without delay in a CASE 880 service-network sourcing program?

List S1024 together with the supported equipment record, 24V, 6.0kW, 10T and CW. Send old-unit photos, order volume, destination and requested timing, plus any private-label or staged-delivery requirement. This keeps the technical selection and the commercial offer aligned from the first response.


How can a distributor prepare a complete claim file for S1024 in a CASE 880 service-network review?

For S1024, provide the delivery lot, installation date, operating hours and a clear fault description. Include photographs of the label, pinion, mounting face and terminals, together with battery and voltage-drop results under cranking load. These records help separate product condition from application, installation, electrical-system or transport-related causes.


S1024 Email for Starter Motor B2B Pricing

A complete RFQ for S1024 should state the application, removed-unit number, physical photographs, quantity, destination and delivery target. Send these details to info@elecdurauto.com for a direct response on the correct 24V 6.0kW 10T CW starter, MOQ, packaging, warranty and shipping choices.


Previous: 
Next: 

Product Category

Tell Us About Your Sourcing Needs

Share your product requirements, target market, and estimated order plan. Our team will help match suitable products and provide a fast quotation for your wholesale program.
Contact us
Heavy-Duty Parts. 
On Time. On Demand.
One-Stop Supplier in China
System
About
Contact Info
+86-189-1502-7366
A2 Block, Shimao Plaza, Changzhou, China
COPYRIGHT © 2025 ELECDURAUTO ALL RIGHTS RESERVED.