S9277
S9277 / 30051600003 / 30051600015 / 30051600041 / 30051600041A / 65.26201-7077 / 65262017076 / 65262017076A / 65262017077 / 65262017077B / 65262017077D / S-80294 / STR85204
Elecdura
Available for qualified orders
20 pcs
7 - 15 Days
Neutral packaging / private-label review
18 Months
S9277 / 30051600003 / 30051600015 / 30051600041 / 30051600041A / 65.26201-7077 / 65262017076 / 65262017076A / 65262017077 / 65262017077B / 65262017077D / S-80294 / STR85204
Doosan crane applications using the supplier-defined 24V 4.5kW 11T CW starter with a module-3 drive
Confirm 24V, 4.5kW, 11T, CW, module 3, three illustrated mounting points, technical-image locating face, technical-image drive-end position, mounting orientation and terminal layout against the removed starter before volume supply.
| Availability: | |
|---|---|
| Quantity: | |
S9277 supports Doosan crane sourcing where buyers need a defined electrical and drive-end match. Its 24V, 4.5kW, 11T CW specification must remain linked to the 24V 4.5kW 11T module-3 starter mapped to the Doosan crane reference group; a visually related unit may belong on a different RFQ line.
Before comparing S9277 prices, state whether the request covers an initial sample, urgent breakdown demand or routine distributor replenishment. Include the full OE reference, application, photographs, quantity and destination so the offer remains connected to the physical unit the customer expects to receive.
| Primary OE reference | S9277 |
| Target application | Doosan crane applications |
| Voltage and output | 24V / 4.5kW |
| Pinion and rotation | 11T / module 3 / CW |
| Mounting-hole reference | three illustrated mounting points |
| Drive-end reference | technical-image locating face; technical-image drive-end position; illustrated mounting-hole orientation |
| OE and cross-reference group | S9277 / 30051600003 / 30051600015 / 30051600041 / 30051600041A / 65.26201-7077 / 65262017076 / 65262017076A / 65262017077 / 65262017077B / 65262017077D / S-80294 / STR85204 |
| Wholesale terms | MOQ 20 pcs / normally 7–15 days after order confirmation |
| Warranty | 18 months under agreed sales terms |
The S9277 dimensional review starts at the mounting face: verify three illustrated mounting points, illustrated mounting-hole orientation and technical-image locating face. Then compare the technical-image drive-end position. The drawing is not a scale template, so record actual measurements and review terminal orientation separately.
For S9277, electrical and mechanical identity must agree: 24V, 4.5kW, 11T, module 3 and CW. Check the terminals and solenoid position before installation. If the old unit differs at one of these points, keep it outside the defined stock line.
The S9277 cross-reference group includes S9277, 30051600003, 30051600015, 30051600041, 30051600041A, 65.26201-7077, 65262017076. These numbers improve search coverage across fleets and supplier systems, but they do not replace a check of 24V, 4.5kW, 11T, CW, mounting geometry and terminals.
If a mixed S9277 enquiry contains different pinions, drive positions or connector layouts, list each complete reference and photograph separately. Elecdura can then return distinct offers instead of placing unlike starters under one broad reference family.
Wholesale planning for S9277 can cover a sample stage, routine replenishment and urgent service demand. Elecdura normally works from 20 pieces, confirms a 7–15 day lead time after order approval and provides an 18-month warranty under the agreed commercial terms.
Stock planning should reflect the supported Doosan crane population, recent consumption and transfer time between service locations. Keeping S9277, the 11T drive and the approved mounting interface visible in the inventory record reduces emergency substitution and improves later reorder accuracy.
The production video gives importers and fleet buyers a view of Elecdura starter assembly and electrical checks. For S9277, use it alongside the product-specific reference, application and physical controls on this page, rather than treating a general factory presentation as evidence of fitment.
Use the complete removed-unit number and exact Doosan crane record. Compare the 11T pinion, three illustrated mounting points, technical-image locating face and terminal side with the old starter. A housing resemblance is insufficient when the drive position, mounting face or cable connection differs.
Record battery voltage at rest and during the start attempt, then test both main cables under load. Check grounds, terminal tightness and the control feed to the solenoid. Supplying those readings with an enquiry for S9277 helps the workshop avoid replacing a sound starter when the actual fault is elsewhere.
Use the complete alternate number, not a shortened series, and attach photographs of the removed unit. The S9277 group is acceptable only when 24V, 4.5kW, 11T, CW and the physical interface agree. A reference conflict should be clarified before samples or bulk quantities are released.
For S9277, use a straight front view to compare the three illustrated mounting points and illustrated mounting-hole orientation; use the side view for technical-image locating face and technical-image drive-end position. Complete the check with 11T, CW and terminal orientation. This combination is more reliable than an angled overall photograph alone.
Plan critical-spare coverage around lifting duty cycles and jobsite response time. Add recent usage, equipment population, transfer time and service level. Elecdura can then separate sample, emergency and replenishment quantities and plan packing or staged delivery around the buyer’s schedule.
Receiving should verify the S9277 label, quantity and packaging before opening sampled cartons. Compare the 11T drive, technical-image locating face, mounting holes and terminal side with the approved record. Any damage, missing protection or physical mismatch should be quarantined with photographs and lot details for prompt review.
Provide the full reference and application, not only a broad brand name. Attach front, side and terminal views of the removed starter and state quantity, destination, required date and packaging needs. For S9277, Elecdura will respond with the matching specification, MOQ, availability, commercial terms and freight choices.
Submit the purchase reference, lot number, installation date and hours in service, then describe the symptom and operating conditions. Photographs and cranking-circuit measurements should accompany the report. This structured record gives Elecdura enough context to evaluate S9277 without assuming that every no-crank complaint originates inside the starter.
Prepare the S9277 enquiry with the exact application, full removed-unit reference, front and terminal-side photos, quantity, destination and target date. Send it to info@elecdurauto.com so Elecdura can return a technically defined offer covering samples or bulk supply, export packing, warranty and delivery options.