28100-OY100
28100-OY100 / NSP130
Elecdura
Available for qualified orders
20 pcs
7 - 15 Days
Neutral packaging / private-label review
18 Months
28100-OY100 / NSP130
equipment identified by starter reference 28100-OY100
Confirm 12V, 1.6kW, 9T, CW rotation, mounting face, pinion and terminals.
| Availability: | |
|---|---|
| Quantity: | |
28100-OY100 gives aftermarket buyers a defined 12V, 1.6kW, 9-tooth clockwise configuration for equipment identified by starter reference 28100-OY100. Link the complete reference group to the buyer's machine or engine record, then approve the mounting geometry, pinion position and terminal layout before releasing distributor stock.
For repeat sourcing of 28100-OY100, use 28100-OY100 / NSP130 as reference evidence and equipment identified by starter reference 28100-OY100 as the application checkpoint. Neither item replaces measurement of the removed starter. Archive the approved sample photos, key dimensions, carton label and inspection date under one buyer part number so purchasing, warehouse and warranty teams work from the same physical definition.
This video introduces Elecdura starter-motor production and supply capabilities. Use the product-specific specification, reference and fitment evidence on this page as the purchasing control for 28100-OY100.
Specification | Product specification and B2B ordering control |
Primary reference | 28100-OY100 |
OE / cross-reference group | 28100-OY100 / NSP130 |
Application scope | equipment identified by starter reference 28100-OY100 |
System voltage | 12V |
Rated power | 1.6kW |
Pinion teeth | 9T |
Rotation | CW / clockwise |
Order verification | Confirm the complete 28100-OY100 / NSP130 group, the 12V, 1.6kW, 9-tooth clockwise configuration and the stated application for equipment identified by starter reference 28100-OY100. Before volume supply, match equipment and engine record, complete OE, mounting face, pinion position and terminal arrangement against the removed unit or approved sample. |
28100-OY100 electrical gate | Approve 28100-OY100 only after the 12V system and 1.6kW working rating agree with the removed unit. |
28100-OY100 drive gate | For 28100-OY100, compare the 9T pinion, clockwise rotation, rest position and engagement depth. |
28100-OY100 mounting gate | Release 28100-OY100 only when the mounting face, locating diameter, bolt pattern and terminal clocking match the approved sample. |
28100-OY100 application gate | Keep equipment identified by starter reference 28100-OY100 and the buyer's engine or machine record attached to the 28100-OY100 approval file. |
28100-OY100 lot gate | Link every 28100-OY100 receiving sample, carton label and inspection result to one supplier production lot. |
MOQ | 20 pcs, subject to final order confirmation |
Normal lead time | 7 - 15 days after order confirmation |
Warranty | 18 months under agreed sales terms |
Use 28100-OY100 as the primary purchasing reference and cross-check NSP130. These numbers identify the candidate starter family, but approval still requires the exact suffix, electrical rating, drive end, mounting geometry, pinion and terminal layout to match the removed unit or signed sample.
Approval point | Order verification for 28100-OY100 |
Reference identity | Match the complete 28100-OY100 / NSP130 group and retain the old-unit label. |
Application record | equipment identified by starter reference 28100-OY100 |
Electrical version | Confirm 12V, 1.6kW, 9T and clockwise rotation. |
Physical match | Compare equipment and engine record, complete OE, mounting face, pinion position and terminal arrangement. |
Commercial release | Link one approved sample, drawing or photo set to the quotation, purchase order and receiving lot. |
Fitment control for 28100-OY100 starts with the old starter and the application record. Compare equipment and engine record, complete OE, mounting face, pinion position and terminal arrangement, and do not force a unit into position with the mounting bolts. If the reference family includes multiple ratings or tooth counts, create separate approval and inventory records for each physical version.
Inspect incoming 28100-OY100 lots against the signed sample and purchase-line specification. Check reference label, electrical rating, drive end, mounting geometry, terminals, packing and lot traceability, record the result by lot and quarantine any mixed version before it reaches saleable inventory. This prevents a low-cost receiving shortcut from becoming an unverified substitute that can stop equipment, generate a claim and turn a low unit price into a costly order.
B2B item | Supply arrangement |
Quality position | Aftermarket replacement for verified reference and fitment |
MOQ | 20 pcs |
Lead time | 7 - 15 days, subject to order confirmation |
Packaging | Neutral packaging or private-label review for qualified orders |
Incoming control | Check reference label, electrical rating, drive end, mounting geometry, terminals, packing and lot traceability. |
Warranty | 18 months under agreed sales terms |
RFQ information | Complete OE, application record, old-unit photos, quantity and destination for 28100-OY100 |
The standard MOQ is 20 pieces, subject to final order confirmation, and a sample or pre-production approval should precede volume release when fitment information is incomplete. Mark the approved sample with 28100-OY100, buyer application and revision date. Repeat orders should reference that same approval plus any packaging specification. If the supplier, suffix or physical design changes, treat it as a new approval rather than assuming the previous decision still applies.
Neutral packaging and private-label review are available for qualified orders. The carton and inner protection should prevent movement, terminal damage and contamination while keeping the product reference, lot identity and quantity readable. Private-label artwork must not remove the technical identifiers used for fitment and claims. Agree label content, barcode needs, carton strength and destination handling before production so the packaging supports both sales presentation and receiving control.
The standard warranty is 18 months under agreed sales terms, but a claim still needs traceable evidence. Record the invoice or lot, installed application, old and supplied references, installation date, symptoms and electrical test results. Include photographs of the unit, terminals, mounting and pinion. Do not dismantle or discard the product before instructions are agreed. Complete evidence speeds technical review and prevents a battery, wiring or ring-gear problem from being misclassified.
Use 28100-OY100 as the control reference and measure and compare the complete group 28100-OY100 / NSP130. A cross-reference narrows the candidate, but it does not prove that every suffix has the same rating or mounting. Retain the removed-unit label, drive-end photograph, mounting-face view and rear-terminal view in the approval file, then connect that evidence to one quotation and purchase line so repeat orders remain traceable.
Confirm the complete 28100-OY100 / NSP130 group together with the 12V, 1.6kW, 9-tooth clockwise configuration. Similar appearance or a shared partial number is not enough; compare equipment and engine record, complete OE, mounting face, pinion position and terminal arrangement against the removed unit or approved sample and keep the signed sample with the purchase record.
Confirm the complete 28100-OY100 / NSP130 group together with the 12V, 1.6kW, 9-tooth clockwise configuration. Similar appearance or a shared partial number is not enough; compare equipment and engine record, complete OE, mounting face, pinion position and terminal arrangement against the removed unit or approved sample and keep the signed sample with the purchase record.
Confirm the complete 28100-OY100 / NSP130 group together with the 12V, 1.6kW, 9-tooth clockwise configuration. Similar appearance or a shared partial number is not enough; compare equipment and engine record, complete OE, mounting face, pinion position and terminal arrangement against the removed unit or approved sample and keep the signed sample with the purchase record.
Measure and compare the equipment and engine record, complete OE, mounting face, pinion position and terminal arrangement with the removed starter. Check bolt-hole spacing, locating diameter, starter clocking, pinion rest position and rear-terminal clearance instead of judging from the outer housing alone. Never pull a misaligned unit into place with mounting bolts. A measured or photographed fitment record is especially valuable when nearby references share the same voltage and tooth count but use another drive-end or solenoid orientation.
Tie every carton and sampled unit to 28100-OY100, the approved reference document and the supplier lot. Inspect reference label, electrical rating, drive end, mounting geometry, terminals, packing and lot traceability, then compare the sampled unit with the signed photos or dimensional document. Record pass and fail quantities before the stock is mixed. Quarantine any different rating, pinion, mounting face or terminal layout, because an unverified substitute can stop equipment, generate a claim and turn a low unit price into a costly order. This receiving discipline is cheaper than sorting returns after distribution.
Send the complete reference, equipment identified by starter reference 28100-OY100, old-unit photos, quantity, destination and packaging or inspection requirements. Elecdura will use that evidence to review one defined aftermarket starter configuration for your quotation.