60086-33110
60086-33110
Elecdura
Available for qualified orders
20 pcs
7 - 15 Days
Neutral packaging / private-label review
18 Months
60086-33110
4D95 applications
Confirm 24V, 4.5kW, 11T, CW rotation, mounting face, pinion and terminals.
| Availability: | |
|---|---|
| Quantity: | |
For repeat wholesale supply, 60086-33110 should remain tied to 4D95 applications and the exact 24V, 4.5kW, 11-tooth clockwise configuration. Record the accepted old-unit label and physical sample so purchasing, receiving and warranty teams do not mix an adjacent starter variant with the approved item.
60086-33110 should enter a wholesale catalog only after the buyer links 60086-33110 to 4D95 applications and a verified sample. Record the mounting pattern, pinion reach, terminal clocking and rating label alongside the commercial terms. When another factory quotes the line, compare that complete record first; a lower price on an adjacent version does not represent the same purchasing outcome.
This video introduces Elecdura starter-motor production and supply capabilities. Use the product-specific specification, reference and fitment evidence on this page as the purchasing control for 60086-33110.
Specification | Product specification and B2B ordering control |
Primary reference | 60086-33110 |
OE / cross-reference group | 60086-33110 |
Application scope | 4D95 applications |
System voltage | 24V |
Rated power | 4.5kW |
Pinion teeth | 11T |
Rotation | CW / clockwise |
Order verification | Confirm the complete 60086-33110 group, the 24V, 4.5kW, 11-tooth clockwise configuration and the stated application for 4D95 applications. Before volume supply, match equipment and engine record, complete OE, mounting face, pinion position and terminal arrangement against the removed unit or approved sample. |
60086-33110 electrical gate | Approve 60086-33110 only after the 24V system and 4.5kW working rating agree with the removed unit. |
60086-33110 drive gate | For 60086-33110, compare the 11T pinion, clockwise rotation, rest position and engagement depth. |
60086-33110 mounting gate | Release 60086-33110 only when the mounting face, locating diameter, bolt pattern and terminal clocking match the approved sample. |
60086-33110 application gate | Keep 4D95 applications and the buyer's engine or machine record attached to the 60086-33110 approval file. |
60086-33110 lot gate | Link every 60086-33110 receiving sample, carton label and inspection result to one supplier production lot. |
MOQ | 20 pcs, subject to final order confirmation |
Normal lead time | 7 - 15 days after order confirmation |
Warranty | 18 months under agreed sales terms |
Use 60086-33110 as the complete purchasing reference. Do not approve a substitute from voltage or appearance alone; the electrical rating, drive end, mounting geometry, pinion and terminal layout must match the removed unit or signed sample.
Approval point | Order verification for 60086-33110 |
Reference identity | Match the complete 60086-33110 group and retain the old-unit label. |
Application record | 4D95 applications |
Electrical version | Confirm 24V, 4.5kW, 11T and clockwise rotation. |
Physical match | Compare equipment and engine record, complete OE, mounting face, pinion position and terminal arrangement. |
Commercial release | Link one approved sample, drawing or photo set to the quotation, purchase order and receiving lot. |
Before accepting 60086-33110 as a replacement, obtain the full vehicle, machine or engine record and compare equipment and engine record, complete OE, mounting face, pinion position and terminal arrangement. Cross-reference overlap is useful for finding the family, but it cannot replace a physical match. Store the approved label and four-angle photo set with the account so later orders use the same configuration.
Receiving control should link the carton, unit label and inspection sample to 60086-33110. Verify reference label, electrical rating, drive end, mounting geometry, terminals, packing and lot traceability; photograph deviations and keep affected units separate while the supplier responds. Batch evidence makes repeat purchases more predictable and gives warranty teams a clear record if field feedback appears.
B2B item | Supply arrangement |
Quality position | Aftermarket replacement for verified reference and fitment |
MOQ | 20 pcs |
Lead time | 7 - 15 days, subject to order confirmation |
Packaging | Neutral packaging or private-label review for qualified orders |
Incoming control | Check reference label, electrical rating, drive end, mounting geometry, terminals, packing and lot traceability. |
Warranty | 18 months under agreed sales terms |
RFQ information | Complete OE, application record, old-unit photos, quantity and destination for 60086-33110 |
The specified application is 4D95 applications. Because a model or engine family can include production changes, confirm the machine, vehicle or engine record and the complete old-unit suffix before promising fitment. Keep the approved record tied to one physical starter configuration.
The specified configuration is 24V, 4.5kW, 11-tooth clockwise configuration. Voltage must match the electrical system, while power, tooth count and rotation affect cranking performance and ring-gear engagement. Put all four values on the sample-approval sheet and verify the physical pinion before releasing a distributor quantity.
Confirm the complete 60086-33110 group together with the 24V, 4.5kW, 11-tooth clockwise configuration. Similar appearance or a shared partial number is not enough; compare equipment and engine record, complete OE, mounting face, pinion position and terminal arrangement against the removed unit or approved sample and keep the signed sample with the purchase record.
Measure and compare the equipment and engine record, complete OE, mounting face, pinion position and terminal arrangement with the removed starter. Check bolt-hole spacing, locating diameter, starter clocking, pinion rest position and rear-terminal clearance instead of judging from the outer housing alone. Never pull a misaligned unit into place with mounting bolts. A measured or photographed fitment record is especially valuable when nearby references share the same voltage and tooth count but use another drive-end or solenoid orientation.
Tie every carton and sampled unit to 60086-33110, the approved reference document and the supplier lot. Inspect reference label, electrical rating, drive end, mounting geometry, terminals, packing and lot traceability, then compare the sampled unit with the signed photos or dimensional document. Record pass and fail quantities before the stock is mixed. Quarantine any different rating, pinion, mounting face or terminal layout, because an unverified substitute can stop equipment, generate a claim and turn a low unit price into a costly order. This receiving discipline is cheaper than sorting returns after distribution.
A substitute is acceptable only when its complete reference relationship, 24V system, 4.5kW rating, 11T, rotation and mounting geometry agree with the approved unit. Similar appearance or a shared partial number is not enough. Ask for application and old-unit evidence, then test or approve a sample before changing the order line. Keep materially different versions separate in inventory so warehouse staff cannot fulfil one inquiry with the wrong variant.
Check battery capacity, voltage drop, start signal, grounds, ring gear and mechanical engine load before condemning the starter. Record battery voltage at rest and during the start command, then measure voltage drop under load; a weak supply or poor ground can imitate starter failure. Inspect the mounting surface and gear engagement as well. Attach these results, the old-unit label and failure symptoms to the claim so the supplier can distinguish a product defect from an upstream electrical or mechanical problem.
Send 60086-33110 and all visible OE or catalog references, the full application or engine record, required quantity, destination and target delivery date. Add clear photos of the label, drive end, mounting face and terminals, plus any dimensional drawing available. State packaging, private-label, sample and inspection requirements at the start. A technically complete RFQ lets the supplier quote one verified configuration and reduces clarification delays after price approval.
The standard MOQ is 20 pieces, subject to final order confirmation, and a sample or pre-production approval should precede volume release when fitment information is incomplete. Mark the approved sample with 60086-33110, buyer application and revision date. Repeat orders should reference that same approval plus any packaging specification. If the supplier, suffix or physical design changes, treat it as a new approval rather than assuming the previous decision still applies.
Send the complete reference, 4D95 applications, old-unit photos, quantity, destination and packaging or inspection requirements. Elecdura will use that evidence to review one defined aftermarket starter configuration for your quotation.