S4D95PC-60
S4D95PC-60 / 4D102T / 0-24000-0030
Elecdura
Available for qualified orders
20 pcs
7 - 15 Days
Neutral packaging / private-label review
18 Months
S4D95PC-60 / 4D102T / 0-24000-0030
equipment identified by starter reference S4D95PC-60
Confirm 24V, 5.0kW, 11T, CW rotation, mounting face, pinion and terminals.
| Availability: | |
|---|---|
| Quantity: | |
S4D95PC-60 gives aftermarket buyers a defined 24V, 5.0kW, 11-tooth clockwise configuration for equipment identified by starter reference S4D95PC-60. Link the complete reference group to the buyer's machine or engine record, then approve the mounting geometry, pinion position and terminal layout before releasing distributor stock.
Treat S4D95PC-60 as one controlled purchasing identity. Keep S4D95PC-60 / 4D102T / 0-24000-0030, equipment identified by starter reference S4D95PC-60, the approved dimensional record and the signed sample together in the sourcing file. If a future offer changes any suffix, rating or drive-end detail, reopen technical approval before comparing price or delivery. This keeps distributor quotations tied to the part actually reviewed rather than to a visually similar starter family.
This video introduces Elecdura starter-motor production and supply capabilities. Use the product-specific specification, reference and fitment evidence on this page as the purchasing control for S4D95PC-60.
Specification | Product specification and B2B ordering control |
Primary reference | S4D95PC-60 |
OE / cross-reference group | S4D95PC-60 / 4D102T / 0-24000-0030 |
Application scope | equipment identified by starter reference S4D95PC-60 |
System voltage | 24V |
Rated power | 5.0kW |
Pinion teeth | 11T |
Rotation | CW / clockwise |
Order verification | Confirm the complete S4D95PC-60 / 4D102T / 0-24000-0030 group, the 24V, 5.0kW, 11-tooth clockwise configuration and the stated application for equipment identified by starter reference S4D95PC-60. Before volume supply, match equipment and engine record, complete OE, mounting face, pinion position and terminal arrangement against the removed unit or approved sample. |
S4D95PC-60 electrical gate | Approve S4D95PC-60 only after the 24V system and 5.0kW working rating agree with the removed unit. |
S4D95PC-60 drive gate | For S4D95PC-60, compare the 11T pinion, clockwise rotation, rest position and engagement depth. |
S4D95PC-60 mounting gate | Release S4D95PC-60 only when the mounting face, locating diameter, bolt pattern and terminal clocking match the approved sample. |
S4D95PC-60 application gate | Keep equipment identified by starter reference S4D95PC-60 and the buyer's engine or machine record attached to the S4D95PC-60 approval file. |
S4D95PC-60 lot gate | Link every S4D95PC-60 receiving sample, carton label and inspection result to one supplier production lot. |
MOQ | 20 pcs, subject to final order confirmation |
Normal lead time | 7 - 15 days after order confirmation |
Warranty | 18 months under agreed sales terms |
Use S4D95PC-60 as the primary purchasing reference and cross-check 4D102T, 0-24000-0030. These numbers identify the candidate starter family, but approval still requires the exact suffix, electrical rating, drive end, mounting geometry, pinion and terminal layout to match the removed unit or signed sample.
Approval point | Order verification for S4D95PC-60 |
Reference identity | Match the complete S4D95PC-60 / 4D102T / 0-24000-0030 group and retain the old-unit label. |
Application record | equipment identified by starter reference S4D95PC-60 |
Electrical version | Confirm 24V, 5.0kW, 11T and clockwise rotation. |
Physical match | Compare equipment and engine record, complete OE, mounting face, pinion position and terminal arrangement. |
Commercial release | Link one approved sample, drawing or photo set to the quotation, purchase order and receiving lot. |
Before accepting S4D95PC-60 as a replacement, obtain the full vehicle, machine or engine record and compare equipment and engine record, complete OE, mounting face, pinion position and terminal arrangement. Cross-reference overlap is useful for finding the family, but it cannot replace a physical match. Store the approved label and four-angle photo set with the account so later orders use the same configuration.
Receiving control should link the carton, unit label and inspection sample to S4D95PC-60. Verify reference label, electrical rating, drive end, mounting geometry, terminals, packing and lot traceability; photograph deviations and keep affected units separate while the supplier responds. Batch evidence makes repeat purchases more predictable and gives warranty teams a clear record if field feedback appears.
B2B item | Supply arrangement |
Quality position | Aftermarket replacement for verified reference and fitment |
MOQ | 20 pcs |
Lead time | 7 - 15 days, subject to order confirmation |
Packaging | Neutral packaging or private-label review for qualified orders |
Incoming control | Check reference label, electrical rating, drive end, mounting geometry, terminals, packing and lot traceability. |
Warranty | 18 months under agreed sales terms |
RFQ information | Complete OE, application record, old-unit photos, quantity and destination for S4D95PC-60 |
Inspect battery capacity, voltage drop, start signal, grounds, ring gear and mechanical engine load before condemning the starter. Record battery voltage at rest and during the start command, then measure voltage drop under load; a weak supply or poor ground can imitate starter failure. Inspect the mounting surface and gear engagement as well. Attach these results, the old-unit label and failure symptoms to the claim so the supplier can distinguish a product defect from an upstream electrical or mechanical problem.
Send S4D95PC-60 and all visible OE or catalog references, the full application or engine record, required quantity, destination and target delivery date. Add clear photos of the label, drive end, mounting face and terminals, plus any dimensional drawing available. State packaging, private-label, sample and inspection requirements at the start. A technically complete RFQ lets the supplier quote one verified configuration and reduces clarification delays after price approval.
The standard MOQ is 20 pieces, subject to final order confirmation, and a sample or pre-production approval should precede volume release when fitment evidence is incomplete. Mark the approved sample with S4D95PC-60, buyer application and revision date. Repeat orders should reference that same approval plus any packaging specification. If the supplier, suffix or physical design changes, treat it as a new approval rather than assuming the previous decision still applies.
Neutral packaging and private-label review are available for qualified orders. The carton and inner protection should prevent movement, terminal damage and contamination while keeping the product reference, lot identity and quantity readable. Private-label artwork must not remove the technical identifiers used for fitment and claims. Agree label content, barcode needs, carton strength and destination handling prior to production so the packaging supports both sales presentation and receiving control.
The standard warranty is 18 months under agreed sales terms, but a claim still needs traceable supporting evidence. Record the invoice or lot, installed application, old and supplied references, installation date, symptoms and electrical test results. Include photographs of the unit, terminals, mounting and pinion. Do not dismantle or discard the product before instructions are agreed. Complete supporting evidence speeds technical review and prevents a battery, wiring or ring-gear problem from being misclassified.
Use S4D95PC-60 as the control reference and cross-check 4D102T, 0-24000-0030. Retain the complete old-unit label plus drive-end, mounting-face and rear-terminal photos with the quotation and purchase line so repeat orders remain tied to the approved unit.
The specified application is equipment identified by starter reference S4D95PC-60. Because a model or engine family can include production changes, confirm the machine, vehicle or engine record and the complete old-unit suffix before promising fitment. Keep the approved record tied to one physical starter configuration.
The specified configuration is 24V, 5.0kW, 11-tooth clockwise configuration. Voltage must match the electrical system, while power, tooth count and rotation affect cranking performance and ring-gear engagement. Put all four values on the sample-approval sheet and verify the physical pinion before releasing a distributor quantity.
Confirm the complete S4D95PC-60 / 4D102T / 0-24000-0030 group together with the 24V, 5.0kW, 11-tooth clockwise configuration. Similar appearance or a shared partial number is not enough; compare equipment and engine record, complete OE, mounting face, pinion position and terminal arrangement against the removed unit or approved sample and keep the signed sample with the purchase record.
Send the complete reference, equipment identified by starter reference S4D95PC-60, old-unit photos, quantity, destination and packaging or inspection requirements. Elecdura will use that evidence to review one defined aftermarket starter configuration for your quotation.