Elecdura
Available for qualified orders
20 pcs
7 - 15 Days
Neutral packaging / private-label review
18 Months
Bedford BF TK, specified as a 24V 4.5kW 11T starter with a specified 40 mm pinion reference
Confirm 24V, 4.5kW, 11T, 40 mm pinion reference, mounting face, drive-end reach, solenoid position, terminal layout against the removed starter before volume supply.
| Availability: | |
|---|---|
| Quantity: | |
This Bedford BF TK replacement is defined for purchasing by its 24V, 4.5kW and 11T configuration with a specified 40 mm pinion reference. Because the product identity does not rely on a public OE number, the application and physical starter must travel together through enquiry, sample approval and repeat ordering.
Send the BF TK vehicle or engine information available on the customer record, along with photographs of the old unit from the mounting face, drive side and terminals. State quantity, destination and required date so the offer can be built around the actual service requirement instead of an invented cross-reference.
| Primary order identity | Bedford BF TK application + listed specification |
| Target application | Bedford BF TK |
| Starter design family | ND type |
| Voltage and output | 24V / 4.5kW |
| Pinion identification | 11T / specified reference 40 mm |
| OE / reference group | Application-and-physical-match record; no guessed OE |
| Wholesale terms | MOQ 20 pcs / normally 7–15 days after order confirmation |
| Warranty | 18 months under agreed sales terms |
Confirm the 24V electrical system and 4.5kW rating first, then count the 11T pinion and check the specified 40 mm reference. Compare the mounting ears and locating face from a straight front image, including the relationship between the pinion center and the flange.
Use a side view to check drive-end reach, motor-body clearance and solenoid position. A terminal-side image should show the battery stud and control connection clearly. These photographs create a repeatable approval record for future orders when no dependable OE number is available.
Use the product description Bedford BF TK 24V 4.5kW 11T in the RFQ and keep the old-unit images attached to that line. Do not introduce a guessed OE number, because an unsupported reference can move the enquiry into another starter family and make later warehouse checking less reliable.
After a sample is accepted, retain the approved gallery views, electrical rating, tooth count, 40 mm reference and customer application under one stock record. The same evidence can then support repeat quotations without introducing an unverified OE number or relying on memory.
Elecdura can support a 20-piece MOQ, normal 7–15 day lead time after order confirmation and an 18-month warranty under agreed sales terms. Packing, labeling and freight are quoted according to the order volume, destination and whether the first shipment is a sample program or routine stock.
For older BF TK fleets, availability planning should reflect the number of active vehicles, recent workshop demand and the time needed to replenish remote branches. A clear physical approval record lets buyers hold a focused service quantity instead of carrying multiple unconfirmed 24V starters.
The video introduces Elecdura starter-motor production and electrical testing for B2B supply. Product selection remains tied to the specific application, electrical rating, pinion and physical checks stated above, while the video helps buyers review factory and quality-control capability.
Use the full Bedford BF TK application description with 24V, 4.5kW, 11T and the specified 40 mm reference. Attach clear photographs of the old starter from the mounting face, side and terminals. Add quantity and destination. This evidence gives Elecdura a concrete identification package without creating an unsupported reference number.
A straight front photograph of the drive-end flange is the starting point because it shows the locating face, mounting-ear positions and pinion relationship without perspective distortion. Follow it with a side view for drive-end reach and a terminal view for cable connections. Together, the three views are stronger than one attractive overall image.
Voltage separates the unit from 12V starters that may share a similar housing, while output helps define the intended cranking duty. Keeping both values with the BF TK application and 11T drive gives sales and warehouse teams a practical identity that remains useful even when a customer cannot provide an OE label.
Count all pinion teeth, compare the listed 40 mm reference and inspect the drive for damage or unexpected wear. The side view should show how far the pinion sits from the flange. Also review the ring gear condition on the vehicle, because damage or a mismatched engagement position can affect a correct starter.
Keep the verified BF TK description, electrical rating and approved physical images in one record. Search candidate references only as possible leads, then require a full geometry and terminal match before adding any number. If the evidence remains incomplete, continue ordering by the verified application-and-specification identity rather than inventing certainty.
Receiving staff should compare carton identification with the purchase record, then inspect sampled units against the approved front, side and terminal photographs. Verify 24V, 4.5kW, 11T, the 40 mm reference and physical condition. Record any exception by lot and keep it outside normal stock until clarified.
Separate the quantity needed for physical evaluation from the quantity intended for normal replenishment. Use active vehicle count, historical usage, delivery time and branch coverage to set the next order. This staged approach protects service availability while avoiding a large commitment before the no-OE identification record has been proven in the market.
Provide the order and lot details, installation date, vehicle information, hours or starts in service and a clear symptom description. Include photographs plus battery, positive-cable and ground voltage-drop readings. These facts allow the review to consider installation and cranking-circuit conditions as well as the starter itself.
For a focused Bedford BF TK quotation, email info@elecdurauto.com with the 24V 4.5kW 11T requirement, old-unit front, side and terminal photographs, quantity, destination and arrival target. Elecdura will confirm the matching unit, packing, lead time and commercial terms.