M2T57673
M2T57673
Elecdura
Available for qualified orders
20 pcs
7 - 15 Days
Neutral packaging / private-label review
18 Months
M2T57673
Ford T3500; 12V, 2.5kW, 12T
Confirm 12T pinion, mounting face, drive reach, solenoid position and terminal orientation, 12V, 2.5kW, solenoid position and terminal layout against the removed starter before volume supply.
| Availability: | |
|---|---|
| Quantity: | |
Elecdura supplies M2T57673 2.5kW for Ford T3500 to parts distributors, rebuilders and fleet-service buyers. This ND Type CCW replacement is specified as 12V, 2.5kW and 12T; keeping those facts beside the application makes sample comparison and repeat purchasing more consistent.
Equipment dealer teams handling urgent replacement should send M2T57673 2.5kW, the Ford T3500 record, required quantity, destination and delivery timing together. Add straight drive-end and terminal-side photographs of the removed starter. Elecdura can then address a controlled first sample, destination-specific packing and the correct physical configuration in one useful commercial offer.
| Primary order identity | M2T57673 2.5kW |
| Target application | Ford T3500 |
| Starter design | ND Type CCW replacement |
| System voltage | 12V |
| Rated output | 2.5kW |
| Pinion identification | 12T / confirm dimensions from the removed unit |
| OE / reference group | M2T57673 |
| Wholesale terms | MOQ 20 pcs / normally 7–15 days after order confirmation |
| Warranty | 18 months under agreed sales terms |
Ask the workshop to photograph 12T pinion, mounting face, drive reach, solenoid position and terminal orientation without perspective distortion. The same photo set should show the mounting register and the pinion position relative to the flange; these points determine whether a starter that looks similar can actually seat and engage correctly.
Before ordering, the buyer should verify 12V, 2.5kW output, 12T pinion and terminal arrangement. Keeping these points together helps warehouse and sales teams avoid switching a similar-looking unit into the Ford T3500 order.
For repeat supply, store M2T57673 2.5kW, Ford T3500, the received lot and the confirmed old-unit photographs together. That record allows a distributor to reorder the same configuration without rebuilding the decision from a loose list of aftermarket numbers.
For urgent replacement, keep M2T57673 2.5kW, Ford T3500, 12V, 2.5kW and 12T on one purchasing record. At goods-in, review label and reference traceability before releasing the lot. This gives the equipment dealer a documented basis for a controlled first sample when the next order is raised.
MOQ, packing and freight should reflect how the buyer will distribute the product. The normal minimum is 20 pieces and preparation is 7–15 days after confirmation; warranty coverage is 18 months under agreed terms, with labeling and documentation settled before shipment.
Demand from a multi-brand powertrain warehouse should keep M2T57673 2.5kW tied to Ford T3500. For urgent replacement, the equipment dealer can use a project-site reserve, link the machine plate to the item and review label and reference traceability at goods-in. This supports a controlled first sample while keeping destination-specific packing visible.
This video shows Elecdura production and electrical-testing capability for starter-motor supply. It supports supplier evaluation; the M2T57673 2.5kW order should still be based on the listed application, electrical data and physical unit checks.
Equipment dealer teams should tie M2T57673 2.5kW to Ford T3500, 12V, 2.5kW, 12T and the removed-unit photographs before requesting price. For urgent replacement, state quantity, destination and delivery timing, then review label and reference traceability. Ask Elecdura to address destination-specific packing and a controlled first sample in the same quotation.
Send the complete M2T57673 reference, Ford T3500 details, quantity, destination and required date. Add clear front, side and terminal photographs of the removed starter. This gives Elecdura enough information to discuss the intended 12V 2.5kW 12T unit, packing, lead time and freight in one focused offer. Link M2T57673 2.5kW photographs to the label and reference traceability record.
Load-test the battery, measure voltage drop on positive and ground circuits, inspect cable lugs and confirm the engine turns freely. Check the ring gear and mounting-ground contact as well. These steps help separate a starter concern from weak batteries, high resistance or mechanical drag that can produce similar symptoms. Retain the M2T57673 2.5kW result for urgent replacement.
Check the machine electrical system, old-starter label and service record before ordering. Keep 2.5kW, 12T and the terminal arrangement in the same comparison. A starter can have a similar flange but the wrong voltage, output or cable layout, so these facts should be confirmed together. This supports a controlled first sample for M2T57673 2.5kW.
A sample is useful when the old label is incomplete, the application record is uncertain or several similar housings are in local stock. Confirm the sample against mounting, drive and electrical details before scaling the order. Keep the accepted photographs and measurements for later purchasing and receiving checks. This supports a controlled first sample for M2T57673 2.5kW.
List every complete alternate on a separate RFQ line and state whether it came from a label, invoice or parts record. Compare voltage, output, pinion, mounting and terminals before treating it as interchangeable. If one point remains uncertain, request a separate offer instead of combining the numbers. File M2T57673 2.5kW with the label and reference traceability check.
No. Tooth count is only one control. The locating face, mounting pattern, pinion reach, solenoid position, terminals and 12V system must also agree with the removed starter. Review the full set before a sample or bulk order is accepted. Link M2T57673 2.5kW photographs to the label and reference traceability record.
Confirm carton count, labels and visible condition before sampling. On selected units, compare the pinion, mounting face, solenoid and terminals with the confirmed record. Isolate any damaged or different unit with carton and lot photographs before the remainder is released to normal Ford T3500 inventory. Retain M2T57673 2.5kW for a controlled first sample and receiving review.
Email info@elecdurauto.com with M2T57673 2.5kW, Ford T3500 details, old-unit photographs, quantity, delivery country and required date. Elecdura will reply with the matching 12V 2.5kW 12T offer, availability, packing, lead time and freight options.